Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Vibration and Control
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Gasparetto, A.
Right arrow Articles by Miani, S.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Dynamic Model of a Rotating Channel Used in the Steel Industry and Implementation of a Controller

Alessandro Gasparetto

Dipartimento di Ingegneria Elettrica, Gestionale e Meccanica, Università di Udine, Via delle Scienze, 208, I-33100 Udine, Italy

Stefano Miani

Dipartimento di Ingegneria Elettrica, Gestionale e Meccanica, Università di Udine, Via delle Scienze, 208, I-33100 Udine, Italy

In the steel industry, the steel bars coming out from the last stand of the rolling train must be conveyed to the cooling bed. For this purpose, various types of devices are used in the different steel factories. In this paper, the rotating channel used in a single steel company is described and investigated. The problem of deriving an adequate dynamic model for the rotating channel is tackled; the model is then exploited to design a controller which can be employed in the real application of the rotating channel. A lumped parameter model of the rotating channel has been designed and used in this work. Moreover, a distributed parameter model has also been implemented, so as to be able to compare the two models and to evaluate the error made by using the lumped parameter model instead of the distributed parameter model. The lumped parameter model has then been used as a basis for the implementation of a time-varying control scheme, which is also presented in the paper. The control has then been successfully tested on an accurate simulator of the plant. The results obtained from the tests have been very encouraging.

Key Words: Flexible structure • modeling • industry • control

Journal of Vibration and Control, Vol. 10, No. 3, 423-445 (2004)
DOI: 10.1177/1077546304038875


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?